labsolutions software (Shimadzu Corporation)
99
Structured Review
Shimadzu Corporation
labsolutions software
Labsolutions Software, supplied by Shimadzu Corporation, used in various techniques. Bioz Stars score: 99/100, based on 7843 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/labsolutions+software/LabSolutions+Series/pmc13049683-3-187-192
Average 99 stars, based on 7843 article reviews
Labsolutions Software, supplied by Shimadzu Corporation, used in various techniques. Bioz Stars score: 99/100, based on 7843 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/labsolutions+software/LabSolutions+Series/pmc13049683-3-187-192
Average 99 stars, based on 7843 article reviews
labsolutions software - by Bioz Stars,
2026-09
99/100 stars
Images
Related Articles
Magnetic Resonance Imaging:Article Title: MRI, unilateral NMR, macro-vision histology, texture and biochemical dataset for studying the tomato during air drying Article Snippet: Type of data , Original MRI Image in dicom Processed MRI images in raw format Avizo project Temporal NMR transversal echo decay signal in text Macrovision images in tiff Tables in text, cvs and xlsx. .. Data collection , MRI images were acquired using 1.5T scanner (Avanto, Siemens) using the SoftwareSYNGO (Siemens, version VB17) for image acquisition. MRI image processing was realized using Avizo 3D Pro (version 2021.2, FEI Company), ImageJ (1.54 g, Wayne Rasband and contributors, National Institute of Health, USA), Matlab 2019a (MathWorks, USA) ans scilab 6.1.1 for image processing ; Unilateral NMR: Transversal signal decay were recorded using Carr Purcell Meiboom Gill (CPMG) pulse sequence on Mobile Universal Surface Explorer (MOUSE, Magritek, Germany) before being processed on Matlab 2022b (MathWorks, USA) Macro-vision: camera: Baumer VCXU31C (Baumer, sensor: Sony IMX252, Baumer SAS, France), macro imaging lens: VS technology 0513 (VS Technology Corporation, Japan), image acquisition: Baumer Camera Explorer (v3.5.2, Baumer SAS, France), image processing: FIJI (ImageJ v1.54 g, Wayne Rasband and contributors, National Institutes of Health, USA) Tissue texture: TA-plus Texture Analyzer (Lloyd Ametek, USA) controlled by Nexygen Plus software (v4.0.1.184, Lloyds Instruments, USA). Biochemical analyses: sugars and acids: absorbance measurement on SAFAS flx-Xenius XM spectrofluorimeter (SAFAS, Monaco), data acquisition on SP2000 software (v7.8.58.3, SAFAS, Monaco). Carotenoids and polyphenols: chromatography on HPLC-DAD Prominence system (Shimadzu, Japan), data acquisition and analysis on Nuclear Magnetic Resonance:Article Title: MRI, unilateral NMR, macro-vision histology, texture and biochemical dataset for studying the tomato during air drying Article Snippet: Type of data , Original MRI Image in dicom Processed MRI images in raw format Avizo project Temporal NMR transversal echo decay signal in text Macrovision images in tiff Tables in text, cvs and xlsx. .. Data collection , MRI images were acquired using 1.5T scanner (Avanto, Siemens) using the SoftwareSYNGO (Siemens, version VB17) for image acquisition. MRI image processing was realized using Avizo 3D Pro (version 2021.2, FEI Company), ImageJ (1.54 g, Wayne Rasband and contributors, National Institute of Health, USA), Matlab 2019a (MathWorks, USA) ans scilab 6.1.1 for image processing ; Unilateral NMR: Transversal signal decay were recorded using Carr Purcell Meiboom Gill (CPMG) pulse sequence on Mobile Universal Surface Explorer (MOUSE, Magritek, Germany) before being processed on Matlab 2022b (MathWorks, USA) Macro-vision: camera: Baumer VCXU31C (Baumer, sensor: Sony IMX252, Baumer SAS, France), macro imaging lens: VS technology 0513 (VS Technology Corporation, Japan), image acquisition: Baumer Camera Explorer (v3.5.2, Baumer SAS, France), image processing: FIJI (ImageJ v1.54 g, Wayne Rasband and contributors, National Institutes of Health, USA) Tissue texture: TA-plus Texture Analyzer (Lloyd Ametek, USA) controlled by Nexygen Plus software (v4.0.1.184, Lloyds Instruments, USA). Biochemical analyses: sugars and acids: absorbance measurement on SAFAS flx-Xenius XM spectrofluorimeter (SAFAS, Monaco), data acquisition on SP2000 software (v7.8.58.3, SAFAS, Monaco). Carotenoids and polyphenols: chromatography on HPLC-DAD Prominence system (Shimadzu, Japan), data acquisition and analysis on Sequencing:Article Title: MRI, unilateral NMR, macro-vision histology, texture and biochemical dataset for studying the tomato during air drying Article Snippet: Type of data , Original MRI Image in dicom Processed MRI images in raw format Avizo project Temporal NMR transversal echo decay signal in text Macrovision images in tiff Tables in text, cvs and xlsx. .. Data collection , MRI images were acquired using 1.5T scanner (Avanto, Siemens) using the SoftwareSYNGO (Siemens, version VB17) for image acquisition. MRI image processing was realized using Avizo 3D Pro (version 2021.2, FEI Company), ImageJ (1.54 g, Wayne Rasband and contributors, National Institute of Health, USA), Matlab 2019a (MathWorks, USA) ans scilab 6.1.1 for image processing ; Unilateral NMR: Transversal signal decay were recorded using Carr Purcell Meiboom Gill (CPMG) pulse sequence on Mobile Universal Surface Explorer (MOUSE, Magritek, Germany) before being processed on Matlab 2022b (MathWorks, USA) Macro-vision: camera: Baumer VCXU31C (Baumer, sensor: Sony IMX252, Baumer SAS, France), macro imaging lens: VS technology 0513 (VS Technology Corporation, Japan), image acquisition: Baumer Camera Explorer (v3.5.2, Baumer SAS, France), image processing: FIJI (ImageJ v1.54 g, Wayne Rasband and contributors, National Institutes of Health, USA) Tissue texture: TA-plus Texture Analyzer (Lloyd Ametek, USA) controlled by Nexygen Plus software (v4.0.1.184, Lloyds Instruments, USA). Biochemical analyses: sugars and acids: absorbance measurement on SAFAS flx-Xenius XM spectrofluorimeter (SAFAS, Monaco), data acquisition on SP2000 software (v7.8.58.3, SAFAS, Monaco). Carotenoids and polyphenols: chromatography on HPLC-DAD Prominence system (Shimadzu, Japan), data acquisition and analysis on Imaging:Article Title: MRI, unilateral NMR, macro-vision histology, texture and biochemical dataset for studying the tomato during air drying Article Snippet: Type of data , Original MRI Image in dicom Processed MRI images in raw format Avizo project Temporal NMR transversal echo decay signal in text Macrovision images in tiff Tables in text, cvs and xlsx. .. Data collection , MRI images were acquired using 1.5T scanner (Avanto, Siemens) using the SoftwareSYNGO (Siemens, version VB17) for image acquisition. MRI image processing was realized using Avizo 3D Pro (version 2021.2, FEI Company), ImageJ (1.54 g, Wayne Rasband and contributors, National Institute of Health, USA), Matlab 2019a (MathWorks, USA) ans scilab 6.1.1 for image processing ; Unilateral NMR: Transversal signal decay were recorded using Carr Purcell Meiboom Gill (CPMG) pulse sequence on Mobile Universal Surface Explorer (MOUSE, Magritek, Germany) before being processed on Matlab 2022b (MathWorks, USA) Macro-vision: camera: Baumer VCXU31C (Baumer, sensor: Sony IMX252, Baumer SAS, France), macro imaging lens: VS technology 0513 (VS Technology Corporation, Japan), image acquisition: Baumer Camera Explorer (v3.5.2, Baumer SAS, France), image processing: FIJI (ImageJ v1.54 g, Wayne Rasband and contributors, National Institutes of Health, USA) Tissue texture: TA-plus Texture Analyzer (Lloyd Ametek, USA) controlled by Nexygen Plus software (v4.0.1.184, Lloyds Instruments, USA). Biochemical analyses: sugars and acids: absorbance measurement on SAFAS flx-Xenius XM spectrofluorimeter (SAFAS, Monaco), data acquisition on SP2000 software (v7.8.58.3, SAFAS, Monaco). Carotenoids and polyphenols: chromatography on HPLC-DAD Prominence system (Shimadzu, Japan), data acquisition and analysis on Software:Article Title: MRI, unilateral NMR, macro-vision histology, texture and biochemical dataset for studying the tomato during air drying Article Snippet: Type of data , Original MRI Image in dicom Processed MRI images in raw format Avizo project Temporal NMR transversal echo decay signal in text Macrovision images in tiff Tables in text, cvs and xlsx. .. Data collection , MRI images were acquired using 1.5T scanner (Avanto, Siemens) using the SoftwareSYNGO (Siemens, version VB17) for image acquisition. MRI image processing was realized using Avizo 3D Pro (version 2021.2, FEI Company), ImageJ (1.54 g, Wayne Rasband and contributors, National Institute of Health, USA), Matlab 2019a (MathWorks, USA) ans scilab 6.1.1 for image processing ; Unilateral NMR: Transversal signal decay were recorded using Carr Purcell Meiboom Gill (CPMG) pulse sequence on Mobile Universal Surface Explorer (MOUSE, Magritek, Germany) before being processed on Matlab 2022b (MathWorks, USA) Macro-vision: camera: Baumer VCXU31C (Baumer, sensor: Sony IMX252, Baumer SAS, France), macro imaging lens: VS technology 0513 (VS Technology Corporation, Japan), image acquisition: Baumer Camera Explorer (v3.5.2, Baumer SAS, France), image processing: FIJI (ImageJ v1.54 g, Wayne Rasband and contributors, National Institutes of Health, USA) Tissue texture: TA-plus Texture Analyzer (Lloyd Ametek, USA) controlled by Nexygen Plus software (v4.0.1.184, Lloyds Instruments, USA). Biochemical analyses: sugars and acids: absorbance measurement on SAFAS flx-Xenius XM spectrofluorimeter (SAFAS, Monaco), data acquisition on SP2000 software (v7.8.58.3, SAFAS, Monaco). Carotenoids and polyphenols: chromatography on HPLC-DAD Prominence system (Shimadzu, Japan), data acquisition and analysis on Article Title: Cost-Efficient and Fast At-Line Assessment of Content and Uniformity in Low-Dose Dimdazenil Capsules Using Transmission Raman Spectroscopy. Article Snippet: The following reagents and test drugs were used in this study: ammonium acetate (analytical reagent grade, batch number: 20160728, purity ≥ 98.0%, Sinopharm Chemical Reagent Co., Ltd., Shanghai, China), acetic acid (guaranteed reagent grade, batch number: 20220121, purity ≥ 99.8%, Sinopharm Chemical Reagent Co., Ltd., Shanghai, China), acetonitrile (liquid chromatography grade, batch number: X8GA1H, purity: 99.999%, Honeywell, Muskegon, MI, USA), and three batches of dimdazenil capsules (batch numbers: A22051301, A22051401, and A22050701, Zhejiang Jingxin Pharmaceutical Co., Ltd., Shaoxing, China). .. The following instruments were used in this study: a transmission Raman spectrometer (TRS100, Agilent, London, UK) with ContentQC spectra acquisition software (version 3.4.6.8, Agilent, London, UK) and Solo data processing software (version 8.6.2, Eigenvector Research Inc., Manson, WA, USA), an HPLC system (LC-2040C, Shimadzu, Kyoto, Japan) with Article Title: Echinophora tenuifolia L. subsp. sibthorpiana Modulates Stress Response and Mitochondrial Quality Under Glucose Stress in Caenorhabditis elegans . Article Snippet: .. The resulting data was analyzed using the Article Title: Fully Automated Serum LC-MS/MS Platform and Pediatric Reference Intervals for Organic Acids, Amino Acids, and Acylcarnitines in Children (Ages 0-6 Years): Toward Quantitative Diagnosis of Inborn Errors of Metabolism. Article Snippet: .. All LC–MS/MS data were processed using Article Title: Phytochemical Profiling and Bioactivity Evaluation of Ganoderma lucidum (Reishi Mushroom) Fractions: In Vitro Antioxidant, Antimicrobial, and Antidiabetic Activities Article Snippet: .. Relative quantification was performed by peak area integration using Article Title: Biodegradation of plasticizer benzyl butyl phthalate by Paenarthrobacter sp. strain M76 in liquid culture and soil microcosms. Article Snippet: Phthalate esters, a plasticizer widely used in various plastic-based consumer products, readily leach into the environment and later on, significantly threaten human health and ecosystems.. Among them, benzyl butyl phthalate (BBP), a significant environmental contaminant, is classified as a hazardous chemical due to its toxic effects on aquatic and terrestrial life forms.. In this study, we evaluated the biodegradation of BBP in batch culture and in soil microcosms using a Gram-positive bacterium, Paenarthrobacter sp. strain M76, isolated from a plastic waste dump yard in Puducherry, India. Article Title: Occurrence and dietary risk assessments of polyethoxylated tallow amine in soybeans. Article Snippet: • The first report of POEA contamination in all soybeans (57.1–522 μg/kg).. • Imported soybeans had > 2 × more POEA residues than domestic soybeans.. • Glyphosate formulations (e.g., Roundup) were key to elevated POEA in Article Title: Application of HepaRG mono- and HepaRG:THP-1 cocultures as immune responsive hepatotoxicity models. Article Snippet: .. Quantification was performed using Chromatography:Article Title: MRI, unilateral NMR, macro-vision histology, texture and biochemical dataset for studying the tomato during air drying Article Snippet: Type of data , Original MRI Image in dicom Processed MRI images in raw format Avizo project Temporal NMR transversal echo decay signal in text Macrovision images in tiff Tables in text, cvs and xlsx. .. Data collection , MRI images were acquired using 1.5T scanner (Avanto, Siemens) using the SoftwareSYNGO (Siemens, version VB17) for image acquisition. MRI image processing was realized using Avizo 3D Pro (version 2021.2, FEI Company), ImageJ (1.54 g, Wayne Rasband and contributors, National Institute of Health, USA), Matlab 2019a (MathWorks, USA) ans scilab 6.1.1 for image processing ; Unilateral NMR: Transversal signal decay were recorded using Carr Purcell Meiboom Gill (CPMG) pulse sequence on Mobile Universal Surface Explorer (MOUSE, Magritek, Germany) before being processed on Matlab 2022b (MathWorks, USA) Macro-vision: camera: Baumer VCXU31C (Baumer, sensor: Sony IMX252, Baumer SAS, France), macro imaging lens: VS technology 0513 (VS Technology Corporation, Japan), image acquisition: Baumer Camera Explorer (v3.5.2, Baumer SAS, France), image processing: FIJI (ImageJ v1.54 g, Wayne Rasband and contributors, National Institutes of Health, USA) Tissue texture: TA-plus Texture Analyzer (Lloyd Ametek, USA) controlled by Nexygen Plus software (v4.0.1.184, Lloyds Instruments, USA). Biochemical analyses: sugars and acids: absorbance measurement on SAFAS flx-Xenius XM spectrofluorimeter (SAFAS, Monaco), data acquisition on SP2000 software (v7.8.58.3, SAFAS, Monaco). Carotenoids and polyphenols: chromatography on HPLC-DAD Prominence system (Shimadzu, Japan), data acquisition and analysis on High Performance Liquid Chromatography:Article Title: MRI, unilateral NMR, macro-vision histology, texture and biochemical dataset for studying the tomato during air drying Article Snippet: Type of data , Original MRI Image in dicom Processed MRI images in raw format Avizo project Temporal NMR transversal echo decay signal in text Macrovision images in tiff Tables in text, cvs and xlsx. .. Data collection , MRI images were acquired using 1.5T scanner (Avanto, Siemens) using the SoftwareSYNGO (Siemens, version VB17) for image acquisition. MRI image processing was realized using Avizo 3D Pro (version 2021.2, FEI Company), ImageJ (1.54 g, Wayne Rasband and contributors, National Institute of Health, USA), Matlab 2019a (MathWorks, USA) ans scilab 6.1.1 for image processing ; Unilateral NMR: Transversal signal decay were recorded using Carr Purcell Meiboom Gill (CPMG) pulse sequence on Mobile Universal Surface Explorer (MOUSE, Magritek, Germany) before being processed on Matlab 2022b (MathWorks, USA) Macro-vision: camera: Baumer VCXU31C (Baumer, sensor: Sony IMX252, Baumer SAS, France), macro imaging lens: VS technology 0513 (VS Technology Corporation, Japan), image acquisition: Baumer Camera Explorer (v3.5.2, Baumer SAS, France), image processing: FIJI (ImageJ v1.54 g, Wayne Rasband and contributors, National Institutes of Health, USA) Tissue texture: TA-plus Texture Analyzer (Lloyd Ametek, USA) controlled by Nexygen Plus software (v4.0.1.184, Lloyds Instruments, USA). Biochemical analyses: sugars and acids: absorbance measurement on SAFAS flx-Xenius XM spectrofluorimeter (SAFAS, Monaco), data acquisition on SP2000 software (v7.8.58.3, SAFAS, Monaco). Carotenoids and polyphenols: chromatography on HPLC-DAD Prominence system (Shimadzu, Japan), data acquisition and analysis on Article Title: Cost-Efficient and Fast At-Line Assessment of Content and Uniformity in Low-Dose Dimdazenil Capsules Using Transmission Raman Spectroscopy. Article Snippet: The following reagents and test drugs were used in this study: ammonium acetate (analytical reagent grade, batch number: 20160728, purity ≥ 98.0%, Sinopharm Chemical Reagent Co., Ltd., Shanghai, China), acetic acid (guaranteed reagent grade, batch number: 20220121, purity ≥ 99.8%, Sinopharm Chemical Reagent Co., Ltd., Shanghai, China), acetonitrile (liquid chromatography grade, batch number: X8GA1H, purity: 99.999%, Honeywell, Muskegon, MI, USA), and three batches of dimdazenil capsules (batch numbers: A22051301, A22051401, and A22050701, Zhejiang Jingxin Pharmaceutical Co., Ltd., Shaoxing, China). .. The following instruments were used in this study: a transmission Raman spectrometer (TRS100, Agilent, London, UK) with ContentQC spectra acquisition software (version 3.4.6.8, Agilent, London, UK) and Solo data processing software (version 8.6.2, Eigenvector Research Inc., Manson, WA, USA), an HPLC system (LC-2040C, Shimadzu, Kyoto, Japan) with Article Title: Biodegradation of plasticizer benzyl butyl phthalate by Paenarthrobacter sp. strain M76 in liquid culture and soil microcosms. Article Snippet: Phthalate esters, a plasticizer widely used in various plastic-based consumer products, readily leach into the environment and later on, significantly threaten human health and ecosystems.. Among them, benzyl butyl phthalate (BBP), a significant environmental contaminant, is classified as a hazardous chemical due to its toxic effects on aquatic and terrestrial life forms.. In this study, we evaluated the biodegradation of BBP in batch culture and in soil microcosms using a Gram-positive bacterium, Paenarthrobacter sp. strain M76, isolated from a plastic waste dump yard in Puducherry, India. Transmission Assay:Article Title: Cost-Efficient and Fast At-Line Assessment of Content and Uniformity in Low-Dose Dimdazenil Capsules Using Transmission Raman Spectroscopy. Article Snippet: The following reagents and test drugs were used in this study: ammonium acetate (analytical reagent grade, batch number: 20160728, purity ≥ 98.0%, Sinopharm Chemical Reagent Co., Ltd., Shanghai, China), acetic acid (guaranteed reagent grade, batch number: 20220121, purity ≥ 99.8%, Sinopharm Chemical Reagent Co., Ltd., Shanghai, China), acetonitrile (liquid chromatography grade, batch number: X8GA1H, purity: 99.999%, Honeywell, Muskegon, MI, USA), and three batches of dimdazenil capsules (batch numbers: A22051301, A22051401, and A22050701, Zhejiang Jingxin Pharmaceutical Co., Ltd., Shaoxing, China). .. The following instruments were used in this study: a transmission Raman spectrometer (TRS100, Agilent, London, UK) with ContentQC spectra acquisition software (version 3.4.6.8, Agilent, London, UK) and Solo data processing software (version 8.6.2, Eigenvector Research Inc., Manson, WA, USA), an HPLC system (LC-2040C, Shimadzu, Kyoto, Japan) with Purification:Article Title: Cost-Efficient and Fast At-Line Assessment of Content and Uniformity in Low-Dose Dimdazenil Capsules Using Transmission Raman Spectroscopy. Article Snippet: The following reagents and test drugs were used in this study: ammonium acetate (analytical reagent grade, batch number: 20160728, purity ≥ 98.0%, Sinopharm Chemical Reagent Co., Ltd., Shanghai, China), acetic acid (guaranteed reagent grade, batch number: 20220121, purity ≥ 99.8%, Sinopharm Chemical Reagent Co., Ltd., Shanghai, China), acetonitrile (liquid chromatography grade, batch number: X8GA1H, purity: 99.999%, Honeywell, Muskegon, MI, USA), and three batches of dimdazenil capsules (batch numbers: A22051301, A22051401, and A22050701, Zhejiang Jingxin Pharmaceutical Co., Ltd., Shaoxing, China). .. The following instruments were used in this study: a transmission Raman spectrometer (TRS100, Agilent, London, UK) with ContentQC spectra acquisition software (version 3.4.6.8, Agilent, London, UK) and Solo data processing software (version 8.6.2, Eigenvector Research Inc., Manson, WA, USA), an HPLC system (LC-2040C, Shimadzu, Kyoto, Japan) with Quantitative Proteomics:Article Title: Phytochemical Profiling and Bioactivity Evaluation of Ganoderma lucidum (Reishi Mushroom) Fractions: In Vitro Antioxidant, Antimicrobial, and Antidiabetic Activities Article Snippet: .. Relative quantification was performed by peak area integration using |